Tumblelog by Soup.io
Newer posts are loading.
You are at the newest post.
Click here to check if anything new just came in.

March 10 2016

firstclassplumbingandhvac

Cooling and heating Your Log Home


Cooling
Needless to say, our forefathers didn't worry excessive about heating their log cabins. Big fireplaces didn't have problem starting to heat up the main one or two rooms they lived in. Needless to say now that log homes are family-sized, people usually have the opinion that there is something different regarding how they may be heated, as well as the nice thing about it is always that a standard system will act as well in the log home like a traditional structure.

Columbia
Just about all log homes are created with a minumum of one fireplace. Initially, we believed that our beautiful soapstone woodstove would heat the entire house, and we'd use our forced-air propane heat being a backup. Alas, we had been all wrong. Because you will find a cathedral ceiling having a big loft, the temperature in the stove goes directly upstairs, requiring two fans to recirculate the warm air. We expected this, but we also thought the temperature would expand sideways to the rest of the open living area (dining-room and kitchen). And not on your health! Even looking at the couch about 15 feet from your stove, I would like a coverlet. I'm uncomfortably chilly with the food prep. I do believe when there were an everyday ceiling, the warmth could have gone where we expected it, nevertheless the number of the cathedral ceiling threw off our calculations. Also, the soapstone stove is designed to be run 24/7, also, since we both benefit money, the stove doesn't enthusiastic until the evening. This woodstove needs to be hot slowly in the chance of cracking the stone, so by the time it is cooking we're ready for bed.

Old-fashioned fireplaces traditionally sucked each of the heat out from the room, but modern designs will be more efficient at recirculating the warmth. One of the most energy-efficient fireplace was made down the middle of your house, and so the stack heat just isn't lost out. Outside stacks can create back drafts when the fire is extinguished, building a new fire harder to light. Should you be considering multiple fireplaces, putting two of them back-to-back (facing adjoining rooms) gives you the opportunity build one chimney with two flues. Or you'll place a fireplace above your furnace, again allowing two flues inside the same chimney. A direct-vent fireplace will take away the chimney, but you will need to discover how to hide the vent on the exterior wall. Or, if you are using a wood-stove, you may run the pipe from the wall and straight up the exterior, constructing a box around the pipe to simulate a chimney. With respect to the look you desire, you might leave the pipe inside the room and send it sky high. This will give more heat.

It's a good idea to think about your heating and air-conditioning needs at the outset of the look phase. Although log homes are naturally energy-efficient, it isn't really a good idea to skimp on the system. You may be capable of heat all of your house with a huge fireplace or wood stove, but the township will likely have minimum standards to satisfy before they issue a building permit. Also, you have to consider resale value. I know of just one individual who attemptedto sell a million-dollar handcrafted log home without a furnace, so when you could possibly suspect, the buyer never arrived. The home was listed as unfinished, and installing the heat after the fact was too daunting an action. The same problem exists by trying to find away out without central air conditioning. Yes, log homes do stay cooler during the summer time, but those "dog days" of August can present you with a superbly miserable night's sleep, plus a potential buyer will most likely stop as tolerant as the original owner. Indeed, our mortgage company would not consider granting a building loan if we didn't include central heat and air.

If you want to preserve ductwork space, you may use forced air heat, with the exact same ductwork serving air conditioner. Propane or oil will be the fuels of in rural areas. If your interior partitions is limited, you'll find businesses that focus on small, high-pressure duct systems that are great for into tight angles; scalping systems usually demand a better initial installation cost. When utilizing traditional ductwork, you wish to keep your angles at the very least, in order that it allows you design very beginning walls that can conveniently carry mid-air directly on the second floor. A wide open layout offers a challenge, simply because you must please remember the upstairs rooms must be heated somehow, and you'll need both supply and return vents to make an efficient ventilation. If you need to use full log interior walls, you must find another way to run the ductwork, electric, and plumbing. We made that mistake, and you will find not enough return vents in your bedroom. The air is stuffy in the summertime time, in spite of the windows open.

Where perform the vents go? Since all of our exterior walls are full log, a number of our vents were put into the bottom. Should your interior walls are sheetrock or tongue-and-groove, place the the vents where they normally go. Another thing I wish there was done was check out the blueprint with the HVAC contractor, because he place the vents in places I discovered most inconvenient. Sometimes it is usually helped, plus some times it wouldn't.

If you're energy-minded and prefer to go out of your thermostat at the very least, you will notice that the southern-facing side from the log home tends to be warmer than the northern exposure. As the sun is likely to sink closer to the horizon over a winter afternoon, it's advantageous to set up your large windows facing south; in the summer, the sun will overlap the cover, so it won't overheat your home. However, you may find that this northern side of your dwelling - which won't get direct sun whatsoever - may be noticeably cooler. The best option would be to put in radiant-floor heating (when you can afford it). Of course this system takes a boiler rather than a furnace, the in-floor heating spreads the temperature evenly throughout your home, eliminating the northern-facing blues. With radiant-floor heating, you'll want to maintain the thermostat steady all the time; the machine is just not designed to be rejected by visiting work. Additionally, you need to use the boiler to heat your warm water as well, eliminating the necessity for a hot-water heater. However, you still have to install ductwork to the air-con.

Overall, the identical considerations apply such as regular construction. We thought we might make do just one zone of hvac, but also in retrospect, two zones would have solved lots of problems. In the end, it's cheaper to acheive it correctly to begin with. Retrofitting a log house is not a piece of cake!

Don't be the product, buy the product!

Schweinderl